Handheld QAM Analyser cum APP, Level et MER Power pro utroque DVB-C et DOCSIS, MKQ012
Description:
MoreLink scriptor MKQ012 QAM Analyser portabilis est, instructus facultatibus metiendis ac resolvendis QAM parametri retiacula DVB-C/DOCSIS.
Product Detail
Product Tags
Product Detail
MoreLink scriptor MKQ012 QAM Analyser portabilis est, instructus facultatibus metiendis ac resolvendis QAM parametri retiacula DVB-C/DOCSIS.
MKQ012 QAM Analyser portabilis est, instructus facultatibus ad metiendas et resolvendas retiaculorum parametri QAM DVB-C/DOCSIS.MKQ012 offert tempus reale mensurae radiophonicae et retis officia quibusvis provisoribus inservientia.Adhiberi potest inter novas institutiones vel sustentationem et opus reparationis partium in retiacula DVB-C/DOCSIS.Munus Wi-Fi embedded, quod permittit utentem ad mensurationem datam et operationem interactivam per APP.
Product Features
Securus operari et configurare per APP
Fast Channel Scan
Provide utilis constellatio
Embedded potens Imaginis Analyzer
eventum mensurae ostendit in phone captiosus per Wi-Fi
Characteres
Support DVB-C et DOCSIS QAM mensurae et analysis
➢ ITU-J83 Annexes A, B, C support
➢ Auto distinguere RF Signum Type: DOCSIS vel DVB-C
➢ User definivit erectum parametrum et limen, duas personas sustineas: consilium A / consilium B
➢ Mensurae accuratae +/-1dB pro Potestate;+/-1.5dB for MER
TCP / UCP / DHCP / HTTP / SNMP firmamentum
Support one 10/100/1000 Mbps Aer Port
Embedded Pugna
QAM Analysis Parameters
➢ 64 QAM / 256 QAM / 4096 QAM (Optio) / OFDM (Option)
RF Power Level: -15 ad + 50 dBmV
➢ Lata potenti hastiludio range: -15dB ad + 15dB
MER: 20 ad 50 dB
Pre-BER and RS correctable count
Post-BER et RS incorrectable count .
Stellation
Hastiludio mensurae
Applications
➢ Cable network mensurae pro DVB-C / DOCSIS
Multi-fluvium vigilantia
Real-time QAM Analysis
Installation and Sustentationem HFC network
Technical Parameters
Interfaces | ||
RF | Feminae F Connector (SCTE-02) | 75 Ω |
RJ45 (1x RJ45 Ethernet port) | 10/100/1000 | Mbps |
DC Jack | 12V/2A DC |
App functiones | ||
Test | User channels defined test | |
Tools | Channel Information | Unius Channel Mensurae: lock status/potentiae gradus/MER/Pre-BER/Post-BER/QAM modus/Annex modus/symbolum rate et spectrum canalis. |
Channel Scan | Scan definitos canales singillatim ostende frequentiam / lock status / signum type / Power Level/MER/Post-BER | |
Sidus | Providere electae canalis constellationem, et gradum potentiae/MER/Pre-BER/Post-BER | |
Spectrum | Support Committitur/Sistere/Center Frequency/Span occasum, et ostende summam potentiam summam. Suscipe ad 3 monitor channel occasum.Plura praebere canalis informationes pro alveo Monitored. |
RF Characteres | ||
Frequentiam dolor (Edge-ut-Edge) | 88 – 1002 88 – 1218 (Optio) | MHz |
Channel Bandwidth (Auto Detection) | 6/8 | MHz |
Modulation | 16/32/64/128/256 4096 (Optio) / OFDM (Option) | QAM |
RF potenti Power Range (sensit) | -15 ad + 50 | dBmV |
Symbolum Rate | 5.056941 (QAM64) 5.360537 (QAM256) 6.952 (64-QAM and 256-QAM) 6.900, 6.875, 5.200 | Msym/s |
Input Impedimentum | 75 | OHM |
Input Redi damnum | > 6 | dB |
Minimum Noise Level | -55 | dBmV |
Channel Power Level Accuracy | +/-1 | dB |
MER | 20 ad 50 (+/-1.5) | dB |
BER | Pre- RS BER et Post- RS BER |
Imaginum Analyzer | ||
Basic Spectrum Analyzer Optiones | Proin / habe / Curre Frequentia Span (Minimum: 6 MHz) RBW (Minimum: 3.7 KHz) Amplitudo cinguli Amplitudo Unitarum (dBm, dBmV, dBuV) | |
Mensuratio | Venalicium Mediocris Apicem Hold Sidus Channel Power | |
Channel Demod | Pre-BER / Post-BER FEC Lock / QAM Mode / Annex Virtus Level / SNR / Symbol Rate | |
Numerus Sample (Maximum) per Span | 2048 | |
Scan Volo @ Sample numerus = MMXLVIII | 1 (TPY). | Secundus |
Da Data | ||
Realtime Data per API | Telnet (CLI) / Web Socket / MIB |
Software Features | |
Protocols | TCP / UCP / DHCP / HTTP / SNMP |
Channel Table | > 80 RF Channels |
Scan tempus totum alveum mensa | Intra 5 minuta ad typicam mensam cum 80 RF canalibus. |
Supported Channel type | DVB-C et DOCSIS |
Morbi viverra | RF Level, QAM Constellatio, MER, FEC, BER, Spectrum Analyzer |
VUL UI | Facile monstrare eventus scan in navigatro interreti. Facile est mutare canales monitores in mensa. Spectrum HFC plantae. Sidus frequentia specifica. |
MIB | PRIVATIS MIBS.Faciliorem accessum ad magna data pro network administratione systemata |
Terrorem Limina | Signum Leve/MER/BER constitui potest per WEB UI vel MIB vel APP, et nuntii trepidi mitti per SNMP DECIPULUM vel in pagina telaris exponi possunt. |
LOG | Potest saltem 3 dies tigna vigilantia et terrorem tigna cum 15min inspectis intervallis pro 80 canalium conformatione. |
Customization | Protocollum apertum et facile coniungi potest cum OSS . |
Firmware Upgrade | Support remotis vel loci firmware upgrade |
Corporalis | |
Dimensiones | 180mm (W) x 92mm (D) x 55mm (H) (Including F connector) |
Pondus | 650+/-10g |
Potestas Supple | Potentiae Inaptor: Input 100-240 VAC 50-60Hz;Output 12V/2A DC Pugna Power Tergum: Li-ion 5600mAH |
Potentia consummatio | < 12W |
Power Button | x1 |
LED | PWR DUXERIT - Green DS DUXERIT - Green US DUXERIT - Green Online DUXERIT - Green Wi-FI DUXERIT - Green |
Environment | |
Operating Temperature | 0 ad 40oC |
operating Umor | X ad XC% (Non-Condensing) |
WEB GUI screenshots
Cras laoreet (Plan B)
Plena Imaginis et Channel Parametri
(Locus Status, QAM Modus, Channel Power, SNR, MER, post BER, Symbolum Rate, Imaginis Inverted)
Sidus
App screenshots
Channel Test
tools
Channel Information
Sidus
Spectrum
Channel Scan